Title

Comparative Effectiveness of 30%TSC and Heparin Lock Solution in Hemodialysis Catheters
Comparative Effectiveness of 30% Trisodium Citrate and Heparin Lock Solutions in Preventing Infection and Dysfunction of Hemodialysis Catheters: a Randomized Controlled Trial (CITRIM Trial)
  • Phase

    Phase 4
  • Study Type

    Interventional
  • Status

    Completed No Results Posted
  • Study Participants

    179
BACKGROUND: Central venous catheters (CVC) are the only option when hemodialysis is needed for patients without definitive vascular access. However, CVC use is associated with complications such as infection, thrombosis, and dysfunction, leading to higher mortality and expenditures. The aim of this study was to compare the effectiveness of 30% trisodium citrate (TSC30%) with heparin as CVC lock solution in preventing catheter-related bloodstream infections (CRBSI) and dysfunction in hemodialysis patients. METHODS: Randomized, double-blind controlled trial comparing the event-free survival of non-tunneled CVC locked with heparin or TSC30% in adult hemodialysis patients.
METHODS Study Design This double blind randomized controlled trial (RCT) was conducted from July 2012 until July 2014 in the dialysis and transplantation unit of a Brazilian university hospital. The patients were randomly assigned to have their catheter locked with either unfractionated sodium heparin 5000 U/mL or 30% trisodium citrate. The randomization was performed through a computer-generated list of random numbers in blocks of six. Patients and investigators were unaware of the treatment assignments. Allocation concealment was performed using opaque, sealed envelopes for assignment.

After each hemodialysis (HD) session, patients assigned to 30%TSC had their catheter lumens flushed with 0.9% sodium chloride and locked with a volume of 30% TSC solution equivalent to the catheter internal lumen. Patients assigned to heparin had their catheter lumens flushed with 0.9% sodium chloride and locked with a volume of 5000 U/mL heparin equivalent to CVC internal lumen. Catheter care was according to international guidelines, including strict asepsis on insertion and exit-site dressing changes after each HD session by staff wearing masks and sterile gloves.

SELECTION OF PATIENTS Patients were eligible for enrollment in the RCT when they were older than 18 years and had chronic or acute renal failure that required hemodialysis through a catheter. Patients admitted to the intensive care ward, receiving a tunneled catheter, with suspected heparin-induced thrombocytopenia, allergy to heparin or TSC30%, with systemic or localized infection or pregnant women were excluded. The site of insertion and specific type of catheter were decided by the interventionist physician.

MAIN OUTCOMES Catheter related bloodstream infection (CRBSI): CRBSI was defined as fever and/or chills during a dialysis session and at least one positive blood culture, with no other obvious cause of infection after careful clinical examination. The management of the CRBSI was performed according to guidelines. Empirical antibiotic therapy was immediately given. The catheter was removed if there was isolation of S. aureus or fungus, or there was no clinical recovery within 48 hours of antibiotic treatment.

Catheter dysfunction: Dysfunction was defined as a persistent inability to obtain a blood flow above 200 mL/min. In this situation, the catheter was removed or exchanged over guidewire.

OTHER PREDICTORS Patients-related: Data was also collected about age, gender, skin color, presence of diabetes, diagnosis of CKD or acute kidney injury, and hemodialysis vintage.

Catheter-related: Site of insertion (jugular, subclavian or femoral vein), and ordinal number of catheter in the same patient (considering only the study period).

STATISTICAL ANALYSIS Calculation of the required sample size was based on main outcomes. It was assumed that the group with heparin lock would have a rate of catheter-related bloodstream infection of 150% greater than that of catheters with TCS30% lock. With a two-sided test, and an alfa error of 5% and 80% of power, it was required 112 catheters for each group.

The primary analysis was made through survival analysis with Cox proportional hazard regression. Initially the investigators proceed to univariate analysis using Kaplan-Meier curves and log rank test for the categorical variables, and univariate Cox regression for continuous variables. The predictors which have a p-value lower than 0.25 in univariate analysis were included in final model. Interactions were checked for any possible association of predictors. The likelihood ratio test was used for compare nested with full models. The proportionality of predictors was verified by introduction of time-dependent variables in the model. If any predictor violates the proportionality assumption, the analysis would be stratified for that predictor. Well-functioning catheters at the end of the study period, catheters removed because patients acquired functional arteriovenous fistula, renal function recovery, changed to peritoneal dialysis or had transplantation were analyzed as censored data. The analysis was all done on intention-to-treat base. All reported p-value are two sided. The analysis was performed using the STATA 11.2 statistical software (Stata Corporation, College Station, TX, USA)

ETHICAL ASPECTS The study protocol was approved by the local review board. Written informed consent was obtained from all patients before enrollment.
Study Started
Jul 31
2012
Primary Completion
Jul 31
2014
Study Completion
Jul 31
2014
Last Update
Sep 29
2015
Estimate

Drug 30% TSC

The patients were randomly assigned to have their catheter locked with either unfractionated sodium heparin 5000 U/mL or 30% trisodium citrate.

  • Other names: 30% trisodium citrate

Drug Heparin

The patients were randomly assigned to have their catheter locked with either unfractionated sodium heparin 5000 U/mL or 30% trisodium citrate.

  • Other names: unfractionated sodium heparin 5000 U/mL

30%TSC Experimental

After each hemodialysis (HD) session, the catheter lumens were flushed with 0.9% sodium chloride and locked with a volume of 30%TSC solution exactly equivalent to the catheter internal lumen.

Heparin 5000 U/mL Active Comparator

After each hemodialysis (HD) session, the catheter lumens were flushed with 0.9% sodium chloride and locked with a volume of unfractionated sodium heparin 5000 U/mL solution exactly equivalent to the catheter internal lumen.

Criteria

Inclusion Criteria:

patients older than 18 years and
with chronic or acute renal failure and
requiring hemodialysis through a catheter.

Exclusion Criteria:

patients admitted to the intensive care ward,
receiving a tunneled catheter,
patients with suspected heparin-induced thrombocytopenia,
patients with allergy to heparin or TSC30%,
patients with systemic or localized infection
pregnant women
No Results Posted