Official Title

A Blinded Study Evaluating the Accuracy and Safety of Cyclotron-produced 99mTc in Adult Patients
  • Phase

    N/A
  • Study Type

    Interventional
  • Status

    Completed No Results Posted
  • Intervention/Treatment

    99mtc ...
  • Study Participants

    60
The purpose of this study is to evaluate technetium-99m (99mTc) pertechnetate produced by a cyclotron as a replacement for 99mTc pertechnetate obtained from a generator containing the parent isotope Molybdenum-99 (99Mo). 99mTc pertechnetate is currently used in nuclear medicine departments across the country. 99Mo is produced by a number of ageing nuclear reactors across the world and severe shortages of the isotope have occurred in the past few years. Cyclotron-produced 99mTc offers an alternative decentralized production method on a regional basis. Since the manufacturing process is different, the safety and efficacy of cyclotron-produced 99mTc pertechnetate must be evaluated in human subjects to enable its routine clinical use.
Study Started
Oct 31
2015
Primary Completion
Apr 30
2017
Study Completion
Apr 30
2017
Last Update
Feb 21
2023

Drug Cyclotron-produced 99mTc

Each research subject will serve as his/her own control, and will undergo imaging using both generator- and cyclotron-produced 99mTc. The study will follow the usual clinical procedure for routine imaging in the nuclear medicine department. All subjects will be contacted by phone or in person the day following the injection of both generator and cyclotron-produced 99mTc to monitor for potential adverse events.

Drug Generator-produced 99mTc

Each research subject will serve as his/her own control, and will undergo imaging using both generator- and cyclotron-produced 99mTc. The study will follow the usual clinical procedure for routine imaging in the nuclear medicine department. All subjects will be contacted by phone or in person the day following the injection of both generator and cyclotron-produced 99mTc to monitor for potential adverse events.

Evaluation of hyperthyroidism Other

For the evaluation of hyperthyroidism each research subject will undergo imaging using both cyclotron-produced 99mTc and the current standard method used at the site for thyroid imaging (either 123I or generator-produced 99mTc). Each study will be performed on a separate day, with flexibility to schedule either study first.

Evaluation of altered osteogenesis by bone scintigraphy Other

For the evaluation of altered osteogenesis by bone scintigraphy each research subject will serve as his/her own control, and undergo imaging using both generator- and cyclotron-produced 99mTc. Each study will be performed on a separate day, with flexibility to schedule either study first.

Criteria

Inclusion Criteria:

WHO performance status 0-2
Older than the age of majority in the province where the study is performed, and be able to consent to the project
Ambulatory and able to lie supine for the duration of the examination.
Able and willing to return for a subsequent visit within 7 days to undergo a repeat examination and participate in a follow-up phone call to monitor for adverse events.

Subject referred for nuclear medicine examination for one of the following indications:

Biochemically documented hyperthyroidism, referred for scintigraphy to evaluate the differential diagnosis of hyperthyroidism or to plan radioiodine treatment.
Referred for bone scintigraphy for the evaluation of metastases, fractures, or inflammatory conditions. Subjects referred for a limited area (localized) bone scan are eligible, provided they agree to undergo a whole-body scan as part of the procedure.

Exclusion Criteria:

Pregnant, planning to become pregnant within 30 days
Severe evolving health problems (unstable coronary disease, liver failure, heart failure, end-stage-renal failure, hospitalized subjects with severe medical conditions) that may confound the assessment of adverse events.

For subjects evaluated for hyperthyroidism:

Recent iodine-containing IV contrast administration (< 6 weeks)
Recent amiodarone usage (< 8 weeks)

For subjects evaluated for bone scintigraphy:

• Recent trauma occurring less than 24 hours prior to the first 99mTc bone scintigraphy examination, or between the first and second 99mTc bone scintigraphy examination.

Women who are breast-feeding are eligible to participate in this study, but must cease breast-feeding for 24 hours following the 99mTc examinations. They can draw their milk and discard it during this period, and use either formula or previously collected milk to feed their child.
No Results Posted