Title

Evaluation of Above the Cuff Suctioning During General Anesthesia
Evaluation of Microaspiration and Efficacy of Above the Cuff Suctioning During General Anesthesia: A Comparison of Two Endotracheal Tubes With Suction Above Cuff With a Standard Endotracheal Tube
  • Phase

    Phase 4
  • Study Type

    Interventional
  • Study Participants

    50
The aim of this prospective, randomized, pilot study is compare ease of tracheal intubation, amount of microaspiration and efficacy of secretion removal using three FDA (Food and Drug Administration)-cleared endotracheal tubes (ETT) after the induction of general anesthesia in the operating room (OR). Studies in the intensive care unit (ICU) have demonstrated a significant reduction in the incidence of ventilator acquired pneumonia when a ETT with suction above the cuff is used to remove secretions that accumulate above the inflated cuff. This will be the first study to evaluate the efficacy of above the cuff suctioning during general anesthesia and surgery.

One hundred and ten adult patients undergoing elective abdominal surgery (general, colorectal or gynecological) requiring general anesthesia with an endotracheal tube and mechanical ventilation will be randomized into 3 groups to receive one of the following three endotracheal tubes:

Teleflex ISIS HVT Cuffed Tracheal Tube with Subglottic Secretion Suction Port Endotracheal Tube (Teleflex ISIS ETT).
Mallinckrodt TaperGuard Evac Endotracheal Tube (TaperGuard Evac ETT).
Mallinckrodt Intermediate Hi-Lo Endotracheal Tube. (Standard ETT)

The first two groups will be compared to standard ETT (third group) regarding easy of tracheal intubation, efficacy of suctioning of secretions, efficacy of sealing the trachea with an inflated ETT cuff by preventing the movement of test dye (methylene blue) from the pharynx into the trachea and incidence of post-operative respiratory complications.
Study Started
Jul 31
2011
Primary Completion
Oct 31
2012
Study Completion
Oct 31
2012
Results Posted
Jun 08
2022
Last Update
Jun 08
2022

Drug methylene blue

A dilute solution of methylene blue (5 ml of 1 % methylene blue solution in saline, 1:1 dilution) will be gently delivered into the hypopharynx using a flexible suction catheter approximately once per hour until trachea is extubated.

  • Other names: Urolene Blue

TaperGuard Evac ETT Experimental

Trachea will be intubated with Mallinckrodt™TaperGuard™ Evac Endotracheal Tube with a suction port to facilitate removal of secretions from the region of the trachea below the vocal cords and above the inflated ETT cuff

Teleflex ISIS ETT Experimental

Trachea will be intubated with Teleflex ISIS HVT Cuffed Tracheal Tube with Subglottic Secretion suction port to facilitate removal of secretions from the region of the trachea below the vocal cords and above the inflated ETT cuff

Standard ETT Active Comparator

Control group of patients will be intubated with a standard ETT without a suction port above the cuff (The Mallinckrodt Intermediate Hi-Lo Endotracheal Tube)

Criteria

Inclusion Criteria:

Scheduled for elective abdominal surgery with an anticipated duration longer than 2 hours.
ASA (American Society of Anesthesiologists) Physical status Classification 1 to 3. (1 - normal healthy patient, 2 - patients with mild systemic disease, 3 - patients with severe systemic disease)
Endotracheal intubation anticipated to be routine (not difficult) based upon preoperative airway assessment

Exclusion Criteria:

Short duration surgery (anticipated < 2 hours) or emergency (non-elective) surgery
ASA Physical status Classification 4 to 5. (4 - patients with severe systemic diseases that is a constant threat to life, 5 - Moribund patients who are not expected to survive without the operation)
Anticipated difficult airway requiring technique other than direct laryngoscopy for intubation of the trachea.
Pregnancy
History of allergic reaction to Methylene Blue medication
Methemoglobinemia, glucose-6-phosphate dehydrogenase (G6PD) deficiency
History of symptomatic chronic obstructive pulmonary disease (asthma, bronchitis, emphysema) or recent pneumonia (< 6 months prior to surgery).
Hypoxemia (hemoglobin oxygen saturation < 90% room air or on O2 at home or in hospital)
History of coagulopathy, IV heparin therapy, or coumadin therapy (INR > 2.5)

Summary

TaperGuard Evac ETT

Teleflex ISIS ETT

Standard ETT

All Events

Event Type Organ System Event Term TaperGuard Evac ETT Teleflex ISIS ETT Standard ETT

Prevention of the Movement of Test Dye (Methylene Blue) From the Pharynx Into Patients' Trachea During Surgery

The primary objective of the pilot study is to evaluate whether there is a difference between the 3 types of ETT in preventing the movement of test dye (methylene blue) from the pharynx into the trachea, past the inflated cuff. After tracheal intubation a small amount of methylene blue will be instilled into patients' pharynx every 60 minutes. The presence or absence of blue dye above and below the ETT cuff will be evaluated every 20 minutes using a video recording fiberoptic bronchoscope.

TaperGuard Evac ETT

Teleflex ISIS ETT

Standard ETT

2.0
number of participants with dye

Evaluation of pH of Secretions Collected Above Endotracheal Tube Cuff During Surgery

Secretions will be continuously suctioned from the suction port of the two ETT with suction above the cuff port (TaperGard Evac ETT and Teleflex ISIS ETT) into a Luken's trap. We will evaluate whether there is a difference in the pH of the aspirate between two ETT with suction above the cuff port.

TaperGuard Evac ETT

7.38
pH (Mean)
Standard Deviation: 0.59

Teleflex ISIS ETT

7.29
pH (Mean)
Standard Deviation: 0.41

the Ease of Tracheal Intubation Following the Induction of General Anesthesia Among the 3 Types of ETT

Time to intubate trachea

TaperGuard Evac ETT

7.53
minutes (Mean)
Standard Deviation: 0.48

Teleflex ISIS ETT

7.59
minutes (Mean)
Standard Deviation: 0.48

Standard ETT

7.41
minutes (Mean)
Standard Deviation: 0.58

Evaluation the Trachea and Vocal Cords at the Time of ETT Extubation to Determine Whether There is a Difference in the Amount of Mucosal Injury Between the 3 Types of ETT.

number of patients with mucosal injury and blood below the vocal cords

TaperGuard Evac ETT

Teleflex ISIS ETT

Standard ETT

Evaluation of Volume of Secretions Collected Above Endotracheal Tube Cuff During Surgery

Secretions will be continuously suctioned from the suction port of the two ETT with suction above the cuff port (TaperGard Evac ETT and Teleflex ISIS ETT) into a Luken's trap.

TaperGuard Evac ETT

13.0
mL (Mean)
Standard Deviation: 10.48

Teleflex ISIS ETT

26.0
mL (Mean)
Standard Deviation: 19.01

Evaluation of Bacterial Load of Secretions Collected Above Endotracheal Tube Cuff During Surgery

Secretions will be continuously suctioned from the suction port of the two ETT with suction above the cuff port (TaperGard Evac ETT and Teleflex ISIS ETT) into a Luken's trap. The number of patients with a bacterial load of the aspirate between two ETT with suction above the cuff port was measured by gram stain of the aspirated secretions.

TaperGuard Evac ETT

Teleflex ISIS ETT

Total

50
Participants

Age, Continuous

54.66
years (Mean)
Standard Deviation: 12.15

BMI

27.16
kg/m^2 (Mean)
Standard Deviation: 3.92

Race and Ethnicity Not Collected

0
Participants

ASA

Sex: Female, Male

Overall Study

TaperGuard Evac ETT

Teleflex ISIS ETT

Standard ETT