Title

Effect of Nitrous Oxide (N2O) on Intraocular Pressure in Healthy Volunteers
Effect of N2O on Intraocular Pressure in Healthy Volunteers
  • Phase

    Phase 4
  • Study Type

    Interventional
  • Study Participants

    20
The purpose of this study is to learn if breathing nitrous oxide (also known as "laughing gas") changes the pressure in a person's eyes. Some patients who need regular eye exams to measure their eye pressure often need to be put to sleep with medicine in order to complete the eye exam. Some of these medicines are known to cause changes in a person's eye pressure. Because of this, such medicines are avoided if the eye doctor needs to measure the patient's eye pressure. One medicine that is frequently used to put patients to sleep is nitrous oxide. No one really knows what effect nitrous oxide might have on a persons' eye pressure. The investigators are interested to see if nitrous oxide causes an increase, decrease, or no change in eye pressure. The investigators also want to investigate if there is a difference in the effects of nitrous oxide on eye pressure between males and females. Understanding these effects of nitrous oxide is important because during such eye exams, the eye doctor uses the pressure measurements to make important decisions about treatment and surgery options for the patient.

The investigators hypothesize that the use of inhaled nitrous oxide (N2O) will result in a decrease in IOP in healthy volunteers.

The investigators aim to determine the magnitude and duration of change, if any, in IOP caused by inhalation of N2O, and to assess if the gender of the patient has a role in this effect.
An initial pre-anesthetic evaluation and physical examination will be performed by an attending anesthesiologist, and an eye exam will be performed by an attending ophthalmologist to determine suitability for inclusion according to the above criteria. Ideally the eye exam will take place immediately prior to conduction of the study. However, logistical restraints may require that the eye exam take place at a separate time/date prior to conduction of the study. IOPs will be measured by the attending ophthalmologist (B.E.) who will be blinded to the actual readings of the Tonopen by means of a small screen, and a single trained observer (E.F.) will record observations from the Tonopen. The nitrous oxide sedation will be managed by the attending anesthesiologist (K.L.). All patients will be monitored throughout using standardized monitoring (continuous EKG, non-invasive BP, and continuous pulse oximetry).
Study Started
Aug 31
2009
Primary Completion
Oct 31
2011
Study Completion
Oct 31
2011
Results Posted
Sep 23
2014
Estimate
Last Update
Sep 23
2014
Estimate

Drug Nitrous oxide

Nitrous oxide sedation by inhalation

  • Other names: N2O

Nitrous oxide administration Experimental

All 20 healthy volunteers had their intraocular pressure (IOP) measured at baseline and then after 3, 6, 9, and 12 minutes of nitrous oxide administration, and then after 5, 10, and 15 minutes of breathing room air. There was therefore only one study arm, with each individual serving as their control for baseline and then intervention values of IOP measurement.

Criteria

Inclusion Criteria:

Adults aged 18-40
American Society of Anesthesiologists Physical Classification System (ASA) Status 1-2
Nil per os (NPO) prior to study (2 hrs clear liquids, 4 hrs milk, 6 hrs light food, 8 hrs heavy/greasy food)

Exclusion Criteria:

Lack of volunteer consent
Pregnancy
History of features suggestive of a difficult airway on pre-anesthetic evaluation and physical examination
Active gastroesophageal reflux disease
Active obstructive sleep apnea
History of recent trauma
History of pneumothorax or lung cyst
History of Vitamin B12 deficiency
History of recent middle ear surgery (<3months)
Current or recent (<3 weeks) respiratory tract infection
Any acute illness or exacerbation of chronic illness such as asthma, chronic lung disease etc.
Any history of cardiac ischemia (angina), myocardial infarction, or cardiac dysrhythmia.
Myopia greater than -3 spherical equivalents or hyperopia greater than +3 spherical equivalents
History of eye surgery of any sort, including refractive surgery, cataracts, and vitrectomy
History of any ocular disease or infection

Summary

Nitrous Oxide Administration

All Events

Event Type Organ System Event Term Nitrous Oxide Administration

Change in Intraocular Pressure During Nitrous Oxide Sedation

Nitrous Oxide Administration

1.05
mmHg (difference in IOP) (Mean)
95% Confidence Interval: -0.81 to 2.9

Age, Continuous

29.6
years (Mean)
Standard Deviation: 6.7

American Society of Anesthesiologists Physical Classification System (ASA) class

1.1
units on a scale (Mean)
Standard Deviation: 0.307

Baseline Mean Arterial Pressure

86.4
mmHg (Mean)
Standard Deviation: 6.8

Baseline Mean Intraocular Pressure (IOP)

11.0
mmHg (Mean)
Standard Deviation: 2.4

Region of Enrollment

Sex: Female, Male

Overall Study

Nitrous Oxide Administration

Drop/Withdrawal Reasons

Nitrous Oxide Administration