Title

Clinical Trial to Evaluate the Accuracy of [99mTc] ThromboView in the Detection of Deep Vein Thrombosis
Phase II Clinical Trial to Evaluate the Accuracy of Anti-Fibrin Humanized Monoclonal Antibody (DI-DD3B6/22-80B3) Fab' Protein Fragment (ThromboView) Conjugated With Technetium-99m in the Detection of Deep Vein Thrombosis
  • Phase

    Phase 2
  • Study Type

    Interventional
  • Study Participants

    94
The assessment of patients with suspected deep vein thrombosis (DVT) is a common clinical scenario that, despite major advances in diagnostic testing, continues to be challenging.

The diagnosis of DVT remains problematic in:

patients with suspected first DVT who have a moderate or high pre-test probability (PTP) for DVT and a normal compression ultrasound (CUS);
patients with suspected recurrent DVT; and
patients in whom CUS or contrast venography is technically difficult or not feasible due to patient characteristics.

In patients with suspected first DVT who have a moderate or high PTP and a normal CUS, DVT occurs in up to 10% of cases. Thus, additional diagnostic testing is required, such as venography or serial CUS, so that DVT is not missed, but these approaches are costly and invasive.

In patients with suspected recurrent DVT, currently used diagnostic approaches are problematic because they all have limitations in differentiating old disease from true recurrent disease.

CUS is technically difficult in selected patients, particularly those who are obese.

Contrast venography is the gold standard diagnostic test for DVT to which all other diagnostic venous imaging modalities for DVT are compared and judged. The Food and Drug Administration (FDA) requires that a new diagnostic test for DVT be assessed against venography.

[99mTc] ThromboView® is a novel diagnostic test based on a 99mTc-labeled monoclonal antibody specific for D-dimer fragments of cross-linked fibrin that are found in acute DVT. After intravenous injection of [99mTc] ThromboView®, there is uptake of the monoclonal antibody by acute, D-dimer rich, venous thrombi. This is visualized with nuclear medicine imaging as an area of increased radioisotope activity that corresponds to the location of DVT.

Based on the biologic and imaging characteristics of [99mTc] ThromboView®, this diagnostic test has the potential to:

identify small non-occlusive proximal DVT or distal DVT in patients with a moderate or high PTP and normal CUS;
differentiate old from new DVT in patients with suspected recurrent DVT;
diagnose or exclude DVT in patients in whom CUS is not technically feasible; and
provide an alternative to venography that is non-invasive, has no contrast-related toxicity and is easily administered.

The present study is the first phase II clinical trial of [99mTc] ThromboView® in patients with suspected initial or recurrent DVT in whom DVT has been confirmed or excluded by venography. A phase II clinical trial to investigate the diagnostic accuracy of [99mTc] ThromboView® is justified because:

ThromboView® was well tolerated, with no significant toxicity in studies involving animals and healthy volunteers; and
it has shown promise in Phase I trials as a non-invasive diagnostic test for acute DVT.
Study Started
Mar 31
2005
Study Completion
May 31
2006
Results Posted
Aug 24
2009
Estimate
Last Update
Aug 24
2009
Estimate

Drug ThromboView

Criteria

Inclusion Criteria:

Adult man or woman, aged ≥18 years, presenting with suspected lower-limb initial or recurrent DVT.
Moderate or high pre-test probability (PTP) for DVT.
Onset of symptoms occurred within the last 7 days.
Women of childbearing potential to have a negative pregnancy test as determined by measuring serum β-hCG levels at time of study enrolment.

Exclusion Criteria:

Receiving anticoagulant therapy at therapeutic doses for >3 days.
Life expectancy <3 months.
Patient with a renal transplant.
Renal dysfunction: serum creatinine >1.5x upper limit of normal range.
Hepatic dysfunction: serum transaminases >3x upper limit of normal range.
Current pregnancy or lactation; or conception intended within 90 days of enrolment
Of childbearing potential and unwilling to use adequate contraception for 30 days following enrolment
Unable to undergo lower limb ascending venography on symptomatic leg(s).
Allergy or other contraindication to intravenous contrast dye.
Prior exposure to murine or humanized antibodies.
Prior imaging studies with: I131 within the last month; In111 or Ga67 within the last 2 weeks; Tc99m labelled RBCs, WBCs or albumin within the last 48 hours; Tc99m or F18 within the last 24 hours; prior non-imaging, non-therapeutic nuclear medicine studies with I131 (eg., 24-hour RAI uptake) within the last 2 weeks.
Previous participation in the present study.
Geographic inaccessibility that precludes follow-up visits.
Patient is unwilling or unable to provide informed consent.
Patient is unsuitable for the study, at the Study Investigator's discretion.

Summary

Group 1

All Events

Event Type Organ System Event Term

To Provide Estimates of the Specificity of [99mTc] ThromboView® in Patients With Excluded Initial DVT

1 Hour Image Set

76.9
% Specificity (Mean)
95% Confidence Interval: 58.0 to 89.0

3 Hour Image Set

65.4
% Specificity (Mean)
95% Confidence Interval: 46.2 to 80.6

15 Min and 1 Hour Image Set

100.0
% Specificity (Mean)
95% Confidence Interval: 87.1 to 100.0

15 Minute and 3 Hour Image Set

96.2
% Specificity (Mean)
95% Confidence Interval: 81.1 to 99.3

To Provide Estimates of the Sensitivity of [99mTc] ThromboView® in Patients With Confirmed Initial DVT.

1 Hour Image Set

37.0
% Sensitivity (Mean)
95% Confidence Interval: 21.5 to 55.8

3 Hour Image Set

74.1
% Sensitivity (Mean)
95% Confidence Interval: 55.3 to 86.8

15 Min and 1 Hour Image Set

11.1
% Sensitivity (Mean)
95% Confidence Interval: 3.9 to 28.1

15 Minute and 3 Hour Image Set

59.3
% Sensitivity (Mean)
95% Confidence Interval: 40.7 to 75.5

To Provide Estimates of the Specificity of [99mTc] ThromboView® for Imaging Suspected Proximal Initial DVT

1 Hour Image Set

86.2
% Specificity (Mean)
95% Confidence Interval: 69.4 to 94.5

3 Hour Image Set

70.0
% Specificity (Mean)
95% Confidence Interval: 52.1 to 83.3

15 Min and 1 Hour Image Set

100.0
% Specificity (Mean)
95% Confidence Interval: 88.3 to 100.0

15 Minute and 3 Hour Image Set

96.7
% Specificity (Mean)
95% Confidence Interval: 83.3 to 99.4

To Provide Estimates of the Sensitivity of [99mTc] ThromboView® for Imaging Suspected Proximal Initial DVT

1 Hour Image Set

42.1
% Sensitivity (Mean)
95% Confidence Interval: 23.1 to 63.7

3 Hour Image Set

90.0
% Sensitivity (Mean)
95% Confidence Interval: 69.9 to 97.2

15 Min and 1 Hour Image Set

15.8
% Sensitivity (Mean)
95% Confidence Interval: 5.5 to 37.6

15 Minute and 3 Hour Image Set

84.2
% Sensitivity (Mean)
95% Confidence Interval: 62.4 to 94.5

To Provide Estimates of the Sensitivity and Specificity of [99mTc] ThromboView® for DVT at the 1-hour and 3-hour Imaging Time Points

Outcome Measure Data Not Reported

To Provide Estimates of the Specificity of [99mTc] ThromboView® for Imaging Suspected Distal Initial DVT

1 Hour Image Set

93.1
% Specificity (Mean)
95% Confidence Interval: 78.0 to 98.1

3 Hour Image Set

89.7
% Specificity (Mean)
95% Confidence Interval: 73.6 to 96.4

15 Min and 1 Hour Image Set

100.0
% Specificity (Mean)
95% Confidence Interval: 88.3 to 100.0

15 Minute and 3 Hour Image Set

96.6
% Specificity (Mean)
95% Confidence Interval: 82.8 to 99.4

To Provide Estimates of the Sensitivity of [99mTc] ThromboView® for Imaging Suspected Distal Initial DVT

1 Hour Image Set

18.2
% Sensitivity (Mean)
95% Confidence Interval: 7.3 to 38.5

3 Hour Image Set

40.9
% Sensitivity (Mean)
95% Confidence Interval: 23.3 to 61.3

15 Min and 1 Hour Image Set

15 Minute and 3 Hour Image Set

36.4
% Sensitivity (Mean)
95% Confidence Interval: 19.7 to 57.1

To Provide Estimates of the Specificity of [99mTc] ThromboView® in Patients With Suspected Recurrent DVT in Whom Disease Recurrence Has Been Excluded

1 Hour Image Set

36.4
% Specificity (Mean)
95% Confidence Interval: 15.2 to 64.6

3 Hour Image Set

72.7
% Specificity (Mean)
95% Confidence Interval: 43.4 to 90.3

15 Min and 1 Hour Image Set

63.6
% Specificity (Mean)
95% Confidence Interval: 35.4 to 84.8

15 Minute and 3 Hour Image Set

72.7
% Specificity (Mean)
95% Confidence Interval: 43.4 to 90.3

Age Continuous

55.12
years (Mean)
Standard Deviation: 15.148

Sex: Female, Male

Overall Study

Group 1

Drop/Withdrawal Reasons